- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources5
- Resource Type
-
0000000005000000
- More
- Availability
-
50
- Author / Contributor
- Filter by Author / Creator
-
-
Vallejo, Daniel D. (4)
-
Fernández, Facundo M. (2)
-
Ruotolo, Brandon T. (2)
-
Arslanoglu, Julie (1)
-
Asef, Carter K. (1)
-
Corstvet, Joseph L (1)
-
Dixit, Sugyan M. (1)
-
Fernández, Facundo M (1)
-
Gadkari, Varun V. (1)
-
Han, Yilin (1)
-
Kulju, Kathryn D. (1)
-
Parson, Kristine F. (1)
-
Polasky, Daniel A. (1)
-
Popowich, Aleksandra (1)
-
Rojas Ramírez, Carolina (1)
-
Tokarski, Caroline (1)
-
Vallejo, Daniel D (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Electrospray ionization (ESI) is one of the most popular methods to generate ions for mass spectrometry (MS). When compared with other ionization techniques, it can generate ions from liquid-phase samples without additives, retaining covalent and non-covalent interactions of the molecules of interest. When hyphenated to liquid chromatography, it greatly expands the versatility of MS analysis of complex mixtures. However, despite the extensive growth in the application of ESI, the technique still suffers from some drawbacks when powered by direct current (DC) power supplies. Triboelectric nanogenerators promise to be a new power source for the generation of ions by ESI, improving on the analytical capabilities of traditional DC ESI. In this review we highlight the fundamentals of ESI driven by DC power supplies, its contrasting qualities to triboelectric nanogenerator power supplies, and its applications to three distinct fields of research: forensics, metabolomics, and protein structure analysis.more » « less
-
Vallejo, Daniel D.; Popowich, Aleksandra; Arslanoglu, Julie; Tokarski, Caroline; Fernández, Facundo M. (, Analytica Chimica Acta)
-
Asef, Carter K.; Vallejo, Daniel D.; Fernández, Facundo M. (, Journal of the American Society for Mass Spectrometry)
-
Vallejo, Daniel D.; Rojas Ramírez, Carolina; Parson, Kristine F.; Han, Yilin; Gadkari, Varun V.; Ruotolo, Brandon T. (, Chemical Reviews)
-
Polasky, Daniel A.; Dixit, Sugyan M.; Vallejo, Daniel D.; Kulju, Kathryn D.; Ruotolo, Brandon T. (, Analytical Chemistry)
An official website of the United States government
